Storage Devices
=================
.. meta::
:description: Drive layout, HDD and SSD selection, controllers, write caches, and benchmarking for Ceph OSD, Monitor, and metadata storage.
:ceph-page-type: reference
Which drives to use for which data, how to connect them, and how to test
them.
Drive Layout
============
.. list-table::
:header-rows: 1
:widths: 28 72
* - Rule
- Detail
* - One OSD per drive
- One :term:`OSD` per HDD, and one per SAS or SATA SSD. Most NVMe SSD
deployments since Quincy do well with one OSD per device; very large
QLC NVMe SSDs, or exceptional RocksDB demands, may benefit from two.
* - A dedicated OS drive
- Use a dedicated, ideally mirrored, drive for the operating system.
Running the OS and OSDs on one drive is a common cause of "slow OSD"
problems, and reimaging the OS then takes the OSD data with it.
* - WAL+DB placement
- SSD OSDs keep the :term:`BlueStore` WAL+DB (write-ahead log and
metadata database) on the same device; offloading it gains nothing.
HDD OSDs, other than the deepest archives, benefit from moving WAL+DB
to a shared SSD: at most 5 HDD OSDs per SAS or SATA offload SSD, and
at most 15 per PCIe Gen 4 or newer NVMe offload SSD. Size each offload
partition or logical volume for the workload; RBD gets by with less
than CephFS or RGW. Since Squid, the minimum suggestion is 2.5 percent
of the bulk device. See :ref:`block and block.db
<bluestore-mixed-device-config>`.
* - No OSD on a Monitor, Manager, or MDS drive
- No exceptions.
* - Minimum OSD size 1 TiB
- OSD drives much smaller than 1 TiB use a significant fraction of
their capacity for metadata. Drives smaller than 100 GiB are not
effective at all.
* - SSDs for Monitors, Managers, and metadata
- Provision enterprise-class SSDs, at a minimum, for hosts that run or
may run Monitor and Manager daemons. Monitor databases, CephFS
metadata pools, and RGW index and log pools require SSDs for
acceptable performance and stability at enterprise scale, even when
HDDs hold bulk OSD data. To keep the CephFS ``metadata`` pool on
SSDs, give it a :term:`CRUSH` rule that selects only SSD media; see
:ref:`CRUSH Device Class <crush-map-device-class>`.
* - Many OSDs per host
- Most hosts run many OSDs, so weigh each host's share of the cluster's
capacity against the full ratio (see :ref:`Failure Domains
<hardware-failure-domains>`) and the aggregate throughput of its
drives against its links (see :ref:`Network Sizing
<hardware-networks>`).
Testing a Drive
===============
BlueStore writes with ``O_DIRECT`` and frequent ``fsync()``, so test the
same way. This ``fio`` example measures 4 KiB random writes:
.. warning:: This test overwrites the device. Run it only on a drive that
holds no data.
.. code-block:: console
# fio --name=osd-test --filename=/dev/sdX --ioengine=libaio --direct=1 --fsync=1 --rw=randwrite --bs=4k --runtime=300
Compare the reported IOPS and completion latency between candidate drives
and between write cache settings.
Setting the Write Cache
=======================
Drives have two write cache modes:
- Volatile write cache enabled (Linux mode "write back"): the volatile cache
is flushed to persistent media with ``fsync``.
- Volatile write cache disabled (Linux mode "write through"): the
non-volatile cache is written synchronously.
Disabling the volatile cache often raises OSD IOPS and lowers commit
latency on HDDs. Do this only on HDDs. Benchmark both settings with ``fio``,
then persist the better one.
Query and change the cache setting, which ``sdparm`` calls WCE (write cache
enable), with any of these tools:
.. list-table::
:header-rows: 1
:widths: 16 42 42
* - Tool
- Query
- Disable
* - ``hdparm``
- ``hdparm -W /dev/sda`` reports ``write-caching = 1 (on)``
- ``hdparm -W0 /dev/sda``
* - ``sdparm``
- ``sdparm --get WCE /dev/sda`` reports ``WCE 1``
- ``sdparm --clear WCE /dev/sda``
* - ``smartctl``
- ``smartctl -g wcache /dev/sda`` reports ``Write cache is: Enabled``
- ``smartctl -s wcache,off /dev/sda``
* - sysfs
- ``cat /sys/class/scsi_disk/*/cache_type`` (for example
``/sys/class/scsi_disk/0:0:0:0/cache_type``) reports ``write back``
- ``echo "write through" > /sys/class/scsi_disk/0:0:0:0/cache_type``
Notes:
- In most cases, disabling the cache with ``hdparm``, ``sdparm``, or
``smartctl`` changes the sysfs ``cache_type`` to ``write through``
automatically. If not, set ``cache_type`` directly as shown in the table.
- ``sdparm`` can view or change the volatile write cache on several
devices at once, for example ``sdparm --get WCE /dev/sd*`` and
``sdparm --clear WCE /dev/sd*``.
- This udev rule, for systemd-based distributions, sets every SATA and SAS
device to ``write through``, SSDs included. Use it only on hosts whose SATA
and SAS drives are all HDDs:
.. code-block:: console
# cat /etc/udev/rules.d/99-ceph-write-through.rules
ACTION=="add", SUBSYSTEM=="scsi_disk", ATTR{cache_type}:="write through"
.. note:: Confirm that the setting persists across reboots. Some drives
require it to be set again at every boot, which the udev rule above
handles.
Setting the I/O Scheduler
=========================
Set the Linux block-layer I/O scheduler to match the class of device
backing each OSD:
* **Rotational (HDD) devices:** ``mq-deadline`` (or ``bfq``). Request
merging and the deadline elevator complement the drive's own command
reordering (NCQ/TCQ) and help avoid read starvation during recovery
and backfill.
* **Solid-state (SSD / NVMe) devices:** ``none``. These devices reorder
requests internally, so a kernel-level elevator only adds latency.
Recent ``blk-mq`` kernels frequently default to these values already, but
this is not guaranteed across distributions, kernel versions, or TuneD
profiles, so it is worth verifying::
# the active scheduler is shown in brackets
cat /sys/block/sda/queue/scheduler
# set it for a single device
echo mq-deadline > /sys/block/sda/queue/scheduler
Make the setting persistent with a ``udev`` rule keyed on
``/sys/block/*/queue/rotational`` so it survives reboots and applies to
devices added later.
Choosing Between HDD and SSD
============================
.. list-table::
:header-rows: 1
:widths: 18 41 41
* - Factor
- HDD
- SSD
* - Access time and IOPS (I/O operations per second)
- Limited by seek time; low IOPS, and lower IOPS per TB as capacity
grows. Slow during recovery.
- Access times at least 100 times faster than HDDs; no seek latency.
Test sequential and random reads and writes; SSDs have limits of
their own.
* - Interface
- The interface becomes a bottleneck at larger capacities. A 32 TB HDD
has ten times the data of a 3 TB HDD behind the same SATA interface.
HDDs above 8 TB suit large, performance-insensitive data.
- NVMe SSDs need no HBA.
* - Recovery
- Very slow recovery can result in a lengthy period of increased risk
after a component fails.
- Substantially faster rebalancing, with less client impact, when OSDs
or Monitors are added, removed, or fail.
* - Cost
- Lower price per terabyte. Chassis management overhead and data center
space are key inputs into TCO (total cost of ownership). Large
deployments often achieve lower TCO with SSDs, especially when the
cost and management of RAID HBAs for HDDs are avoided.
- Higher price per terabyte, but the amortized drive cost for a given
number of IOPS is much lower.
* - Suitability
- Bulk OSD data. Offload WAL+DB onto an SSD; see Drive Layout.
- The metadata pools listed under Drive Layout, and any pool where
performance matters.
Chassis and interface considerations for HDDs:
- Consider not only the interface of a single drive but the system as a
whole. Chassis with SAS or SATA ports connect drives through a backplane,
and chassis that house more than 8 such drives require expanders. In dense
chassis, where 24, 36, or even 100 drives contend for these shared paths,
backplanes and expanders are shared bottlenecks. NVMe drives avoid them.
- A chassis built for LFF (3.5") drives is space-inefficient when SFF
(2.5") drives are fitted through adapters.
- To weigh the factors that determine the total cost of storage, use the
`Storage Networking Industry Association's Total Cost of Ownership
calculator`_.
SSD Selection
=============
.. important:: Before a significant SSD purchase, test the model with the
``fio`` command under `Testing a Drive`_. Test sequential and random
reads and writes, not IOPS alone.
.. list-table::
:header-rows: 1
:widths: 28 72
* - Criterion
- Recommendation
* - Class
- Enterprise-class SSDs. They feature power loss protection (PLP,
capacitors that let the drive finish in-flight writes when power is
lost) and do not suffer the dramatic "cliffing" of client (desktop)
models, where sustained performance declines considerably once a
limited cache fills. Client-class and off-brand SSDs are a false
economy.
* - Endurance for OSDs
- Most OSD deployments do not require more than 1 DWPD (Drive Writes
Per Day, also called "read-optimized"). "Mixed-use" SSDs in the
3 DWPD class are often overkill and cost significantly more. A drive
rated for 0.3 DWPD may be fine for OSDs dedicated to
sequentially-written, read-mostly data, but is not a good choice for
an RBD pool serving hundreds of VMs.
* - Boot plus Monitor or Manager SSD
- For a single SSD, or mirrored pair, that holds both the OS and
Monitor or Manager data: 256 GB minimum, and at least 960 GB
recommended. Choose a model rated at 1+ DWPD or the equivalent in
TBW (TeraBytes Written). A larger SSD lasts longer.
* - Partition alignment
- Align partitions, if any, properly. Improperly aligned partitions
reduce performance and endurance. For details and example commands,
see `Werner Fischer's blog post on partition alignment`_.
Choosing a Controller (HBA)
===========================
Disk controllers (HBAs) can have a significant impact on write throughput.
.. list-table::
:header-rows: 1
:widths: 28 72
* - Controller
- Guidance
* - RAID HBA (IR mode, RAID-on-Chip)
- May exhibit higher latency than a plain HBA. A RAID HBA with cache
and battery adds purchase cost and yearly support cost. Software
mirroring (Linux MD or ZFS) is enough for boot volumes. RAID HBAs are
also fussy and flaky, and almost nobody monitors them well. Many RAID
HBAs can be configured with an IT-mode "personality" or "JBOD mode"
for streamlined operation.
* - Plain HBA (IT or JBOD mode)
- Lower latency and lower cost. Forgoing HBA RAID with SAS or SATA
drives narrows the HDD versus SSD cost gap.
* - NVMe SSDs
- Need no HBA at all. This further narrows the HDD versus SSD cost gap
when the system as a whole is considered.
Additional Resources
====================
- :ref:`hardware-recommendations`
- :ref:`minimum-hardware`
- :ref:`CPU and Memory Sizing <hardware-cpu-memory>`
- :ref:`Network Sizing <hardware-networks>`
- :ref:`block and block.db <bluestore-mixed-device-config>`